‘Ex e’ means that an enclosure is constructed and certified as Explosion Protected according to the Increased Safety standard. …

What is ex in hazardous classification?

Ex rated equipment refers to equipment that has been classified as safe for use in hazardous areas, which are often referred to as “Ex areas.” Non-Ex equipment may emit small sparks or reach high temperatures that can ignite in hazardous areas, causing explosions or fires.

What classification is explosion proof?

There are three classes of explosion proof lights known as Class I, Class II, and Class III. These are the broadest sense in which explosion proof lights are distinguished from each other. The classes are each broken down further into two separate divisions.

What is Ex e protection?

Increased Safety (Ex e): This method of protection prevents explosions by eliminating any source of ignition. Thus no arcing components are permitted.

What is ATEX category?

ATEX Category 1 equipment can be used in any workplace that is governed by ATEX 137, the Workplace Directive (99/92/EC). IPU designs and manufactures engine starting systems for fire pumps, gensets, compressors, winches and industrial vehicles. We serve numerous customers in the oil, gas and mining industries.

How do I read an ATEX certificate?

What is an ATEX coding? The ATEX code is an alphanumeric string that denotes the certification achieved by the product along with the environment and conditions it is suitable for. The code can be broken down into a prefix, for example: CE0518 Ex II 2 G and suffix, for example: Ex d IIC T6 Gb.

What is ex classification?

Products for an explosive environment (Ex/ATEX) are labelled in a standardised manner. All electrical and many non-electrical products that are to be taken into an explosive environment have to satisfy specific Ex/ATEX requirements and must be labelled in a standardised way. …

What does ex nA mean?

An “Ex nA” (non-arcing) marking, prior to a change in the International Electrotechnical Commission (IEC) Standards, was used to designate electrical devices safe to be installed and used in hazardous locations because of the specific protection technique for non-arcing equipment – absence of an ignition source.

Does Class 1 Div 2 require explosion proof?

While Division 1 motors in Class I locations must be explosion-proof, Class II, Division 1 motors must be dust- ignition-proof. The characteristics of dust-ignition-proof motors differ from those of their Class I counterparts.

Which is better Ex d’or Ex e?

Ease of Installation An Ex d luminaire therefore tends to be bigger, bulkier, and heavier than a comparable Ex e fitting. By being lighter and more compact, Ex e luminaires are easier to install and maintain.

Whats the difference between ATEX and Dsear?

DSEAR is for the assessment of a dangerous substance (gas, liquid, dust etc.) and ATEX provides guidance on the type of equipment you should use in each area once you have classified them as the result of an assessment.

Is ATEX a legal requirement?

ATEX Directive 2014/34/EU is mandatory for manufacturers as of 20 April 2016 as stated in article 44 of the Directive.